Customization: | Available |
---|---|
Function: | Steam Boilers |
Fuel: | Waste Heat |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1 | High heat transfer efficiency. The welding fusion rate of fins with steel pipes can reach up to 95%. low contact resistance, good heat transfer performance. |
2 | Low flow resistance |
3 | Less dust |
4 | Less wear and tear |
5 | Small size and light weight |
Ser. No. | Description | Paramters |
1 | Operating pressure | 1.0MPa |
2 | Design pressure | 1.1MPa |
3 | Operating temperature(inlet/outlet) ºC | 60/184ºC |
4 | Design temperature | 200ºC |
5 | Hydraulic test pressure | 1.4MPa |
6 | Maximum dimension: length ×diameter | 2885×Φ1525 (mm) |